*2013/12/16 14:16:17.14 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 09:01:00.000 NUMBER OF RECORDS : 52 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.1 207.9 2 Temperature 'deg C (IPTS68)' 7.829 8.157 3 Salinity ppt 28.899 30.785 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 2 EVENT NUMBER : 122 LATITUDE : 48 49.80000 N ! (deg min) LONGITUDE : 123 0.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:17:01 181 181 DELETE 4.4 2000/01/25 13:57:16 181 52 HDREDIT2 1.6 2003/06/13 11:45:07 ? ? CLEAN 4.2 2003/06/13 11:45:34 52 52 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 52 52 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.1 7.939 29.398 0.2 7.937 29.423 0.3 7.935 29.408 0.5 7.931 29.368 0.6 7.928 29.282 0.6 7.931 29.250 1.1 7.931 29.192 2.0 7.925 29.276 3.1 7.917 29.283 4.0 7.915 29.243 5.2 7.930 28.899 10.2 7.829 29.033 15.2 7.955 29.622 20.1 7.983 29.744 25.0 8.022 29.816 30.0 8.042 29.898 35.1 8.052 29.939 40.0 8.054 29.976 45.1 8.055 29.979 50.1 8.055 29.989 55.1 8.061 30.051 60.1 8.065 30.064 65.0 8.074 30.099 70.0 8.089 30.144 75.2 8.104 30.293 80.2 8.108 30.345 85.1 8.112 30.377 90.0 8.112 30.360 95.3 8.111 30.370 100.1 8.111 30.381 105.2 8.113 30.438 110.2 8.113 30.454 115.1 8.116 30.447 120.0 8.117 30.482 125.2 8.122 30.485 130.0 8.123 30.484 135.2 8.128 30.586 140.4 8.126 30.596 145.1 8.132 30.574 150.2 8.130 30.600 155.2 8.131 30.597 160.0 8.129 30.594 165.4 8.133 30.603 170.1 8.132 30.609 175.3 8.132 30.623 180.1 8.136 30.614 185.0 8.138 30.632 190.1 8.140 30.674 195.2 8.146 30.689 200.1 8.147 30.683 205.2 8.153 30.750 207.9 8.157 30.785