*2013/12/16 14:16:17.02 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 06:24:00.000 NUMBER OF RECORDS : 47 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.2 195.1 2 Temperature 'deg C (IPTS68)' 7.998 8.169 3 Salinity ppt 28.818 30.866 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 1 EVENT NUMBER : 115 LATITUDE : 48 48.50000 N ! (deg min) LONGITUDE : 123 1.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:16:38 106 106 DELETE 4.4 2000/01/25 13:57:13 106 47 HDREDIT2 1.6 2003/06/13 11:45:07 ? ? CLEAN 4.2 2003/06/13 11:45:33 47 47 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 47 47 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.2 8.101 28.841 0.4 8.102 28.839 0.6 8.101 28.855 0.9 8.100 28.846 1.2 8.101 28.862 2.1 8.100 28.859 3.1 8.100 28.869 4.2 8.102 28.818 5.0 8.100 28.864 10.1 8.094 28.949 15.1 8.065 29.060 20.1 8.002 29.372 25.0 8.001 29.488 30.0 8.016 29.622 35.2 8.020 29.641 40.2 8.020 29.688 45.1 8.024 29.691 50.1 8.022 29.705 55.1 8.017 29.768 60.2 8.010 29.764 65.2 7.998 29.824 70.1 8.024 29.877 75.4 8.032 29.888 80.0 8.031 29.905 85.3 8.030 29.906 90.2 8.029 29.935 95.0 8.029 30.006 100.2 8.044 30.072 105.0 8.050 30.132 110.1 8.072 30.270 115.1 8.086 30.288 120.0 8.096 30.365 125.1 8.099 30.416 130.0 8.104 30.467 135.1 8.119 30.580 140.2 8.122 30.600 145.0 8.131 30.666 150.2 8.135 30.690 155.0 8.141 30.726 160.1 8.146 30.726 165.2 8.146 30.728 170.0 8.150 30.739 175.1 8.154 30.806 180.3 8.156 30.811 185.0 8.160 30.825 190.2 8.165 30.866 195.1 8.169 30.863