*2013/12/16 14:16:16.98 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 05:21:00.000 NUMBER OF RECORDS : 25 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.4 85.1 2 Temperature 'deg C (IPTS68)' 7.96 8.344 3 Salinity ppt 29.501 30.046 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 5 EVENT NUMBER : 113 LATITUDE : 48 53.80000 N ! (deg min) LONGITUDE : 122 56.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:16:35 105 105 DELETE 4.4 2000/01/25 13:57:12 105 25 HDREDIT2 1.6 2003/06/13 11:45:06 ? ? CLEAN 4.2 2003/06/13 11:45:33 25 25 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:16 25 25 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.4 8.334 29.512 0.5 8.333 29.513 0.6 8.333 29.517 0.9 8.334 29.525 1.4 8.335 29.517 2.0 8.336 29.517 3.0 8.332 29.518 4.0 8.334 29.509 5.0 8.330 29.511 10.2 8.332 29.501 15.0 8.344 29.536 20.1 8.175 29.559 25.3 8.137 29.581 30.0 8.066 29.595 35.1 8.011 29.651 40.0 7.999 29.651 45.1 7.998 29.661 50.2 7.994 29.666 55.0 7.977 29.687 60.3 7.970 29.704 65.1 7.965 29.742 70.0 7.960 29.770 75.3 7.968 29.862 80.0 7.988 29.925 85.1 8.019 30.046