*2013/12/16 14:16:16.95 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 04:34:00.000 NUMBER OF RECORDS : 49 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.6 215.1 2 Temperature 'deg C (IPTS68)' 8.052 8.166 3 Salinity ppt 29.208 30.842 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 3 EVENT NUMBER : 111 LATITUDE : 48 50.90000 N ! (deg min) LONGITUDE : 122 59.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:16:32 93 93 DELETE 4.4 2000/01/25 13:57:11 93 49 HDREDIT2 1.6 2003/06/13 11:45:06 ? ? CLEAN 4.2 2003/06/13 11:45:33 49 49 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:16 49 49 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.6 8.125 29.239 0.6 8.132 29.224 1.0 8.126 29.208 2.0 8.112 29.242 3.0 8.133 29.218 4.1 8.120 29.245 5.2 8.123 29.230 10.1 8.070 29.577 15.1 8.062 29.577 20.1 8.059 29.610 25.1 8.061 29.625 30.1 8.064 29.605 35.3 8.064 29.631 40.1 8.052 29.670 45.1 8.058 29.710 50.2 8.060 29.741 55.1 8.059 29.792 60.1 8.060 29.818 65.1 8.056 29.894 70.1 8.065 29.938 75.1 8.067 29.955 80.0 8.067 29.955 85.3 8.070 30.020 90.0 8.075 30.029 95.0 8.078 30.096 100.2 8.092 30.225 105.1 8.094 30.262 110.2 8.098 30.300 115.1 8.112 30.402 120.1 8.111 30.419 125.2 8.113 30.417 130.1 8.115 30.407 135.1 8.116 30.410 140.2 8.116 30.439 145.0 8.119 30.426 150.2 8.116 30.413 155.0 8.120 30.424 160.0 8.119 30.435 165.1 8.122 30.456 170.2 8.119 30.455 175.1 8.124 30.458 180.0 8.124 30.465 185.0 8.127 30.504 190.2 8.132 30.592 195.1 8.137 30.607 200.3 8.151 30.731 205.5 8.157 30.792 210.0 8.162 30.784 215.1 8.166 30.842