*2013/12/16 14:16:16.84 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 02:04:00.000 NUMBER OF RECORDS : 50 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.4 215.1 2 Temperature 'deg C (IPTS68)' 8.041 8.183 3 Salinity ppt 28.284 30.977 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 3 EVENT NUMBER : 105 LATITUDE : 48 50.90000 N ! (deg min) LONGITUDE : 122 59.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:16:22 90 90 DELETE 4.4 2000/01/25 13:57:07 90 50 HDREDIT2 1.6 2003/06/13 11:45:06 ? ? CLEAN 4.2 2003/06/13 11:45:33 50 50 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:16 50 50 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.4 8.133 28.421 0.5 8.134 28.317 0.6 8.138 28.295 1.1 8.137 28.284 2.0 8.111 28.592 3.0 8.113 28.630 4.2 8.115 28.746 5.2 8.092 29.058 10.4 8.053 29.507 15.0 8.054 29.507 20.1 8.063 29.273 25.3 8.066 29.403 30.0 8.060 29.465 35.1 8.059 29.476 40.1 8.063 29.450 45.3 8.062 29.473 50.1 8.048 29.522 55.0 8.043 29.525 60.2 8.041 29.545 65.1 8.050 29.862 70.2 8.052 29.908 75.3 8.050 29.949 80.2 8.049 29.941 85.1 8.051 29.961 90.1 8.051 29.964 95.0 8.051 29.984 100.1 8.054 29.971 105.0 8.053 29.997 110.2 8.053 29.977 115.4 8.056 30.010 120.0 8.059 30.103 125.1 8.064 30.161 130.0 8.070 30.169 135.2 8.073 30.206 140.1 8.072 30.184 145.2 8.075 30.175 150.1 8.072 30.179 155.0 8.076 30.182 160.1 8.071 30.178 165.1 8.072 30.184 170.0 8.075 30.160 175.1 8.073 30.206 180.0 8.076 30.193 185.0 8.083 30.258 190.1 8.121 30.502 195.1 8.138 30.679 200.1 8.163 30.839 205.1 8.163 30.890 210.0 8.182 30.977 215.1 8.183 30.967