*2013/12/16 14:16:16.66 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/21 21:00:00.000 NUMBER OF RECORDS : 25 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.4 85.2 2 Temperature 'deg C (IPTS68)' 7.925 8.406 3 Salinity ppt 29.485 30.032 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 5 EVENT NUMBER : 95 LATITUDE : 48 53.80000 N ! (deg min) LONGITUDE : 122 56.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:16:07 136 136 DELETE 4.4 2000/01/25 13:57:02 136 25 HDREDIT2 1.6 2003/06/13 11:45:06 ? ? CLEAN 4.2 2003/06/13 11:45:32 25 25 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:16 25 25 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.4 8.404 29.493 0.5 8.404 29.504 0.7 8.400 29.486 0.8 8.395 29.519 1.1 8.395 29.507 2.3 8.399 29.493 3.3 8.403 29.499 4.3 8.406 29.485 5.0 8.403 29.493 10.1 8.349 29.562 15.0 8.269 29.640 20.2 8.074 29.690 25.0 7.961 29.751 30.0 7.942 29.809 35.3 7.932 29.839 40.1 7.930 29.832 45.3 7.929 29.851 50.2 7.925 29.857 55.0 7.925 29.889 60.2 7.931 29.898 65.2 7.930 29.899 70.0 7.935 29.898 75.2 7.949 29.952 80.2 7.973 30.009 85.2 7.981 30.032