*2013/12/16 14:16:16.06 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/21 07:34:00.000 NUMBER OF RECORDS : 25 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.1 85.1 2 Temperature 'deg C (IPTS68)' 7.955 8.29 3 Salinity ppt 29.419 29.998 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 4 EVENT NUMBER : 64 LATITUDE : 48 52.30000 N ! (deg min) LONGITUDE : 122 57.50000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:15:09 62 62 DELETE 4.4 2000/01/25 13:56:46 62 25 HDREDIT2 1.6 2003/06/13 11:45:04 ? ? CLEAN 4.2 2003/06/13 11:45:31 25 25 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:16 25 25 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.1 8.288 29.436 0.3 8.290 29.435 0.4 8.288 29.430 0.7 8.289 29.428 1.0 8.288 29.419 2.0 8.289 29.430 3.1 8.288 29.428 4.0 8.287 29.431 5.0 8.288 29.447 10.3 8.290 29.444 15.1 8.158 29.528 20.1 7.981 29.672 25.0 7.962 29.656 30.0 7.961 29.670 35.1 7.956 29.708 40.1 7.955 29.806 45.2 7.957 29.803 50.1 7.955 29.798 55.2 7.961 29.826 60.2 7.968 29.886 65.2 7.970 29.877 70.1 7.972 29.882 75.2 7.973 29.913 80.0 7.972 29.926 85.1 7.979 29.998