*2013/12/16 14:16:15.99 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/21 04:11:00.000 NUMBER OF RECORDS : 57 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.5 250 2 Temperature 'deg C (IPTS68)' 7.92 8.221 3 Salinity ppt 29.257 31.01 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : B P EVENT NUMBER : 60 LATITUDE : 48 48.00000 N ! (deg min) LONGITUDE : 122 58.50000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:14:58 125 125 DELETE 4.4 2000/01/25 13:56:42 125 57 HDREDIT2 1.6 2003/06/13 11:45:04 ? ? CLEAN 4.2 2003/06/13 11:45:31 57 57 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:15 57 57 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.5 7.922 29.316 0.8 7.920 29.315 0.9 7.924 29.257 1.1 7.924 29.271 2.0 7.935 29.278 3.0 7.941 29.342 4.1 7.952 29.345 5.1 7.941 29.321 10.1 7.972 29.261 15.0 7.979 29.290 20.1 7.984 29.374 25.2 7.986 29.345 30.0 7.993 29.301 35.1 7.986 29.406 40.0 7.988 29.345 45.1 7.979 29.515 50.1 7.982 29.489 55.2 7.989 29.456 60.1 7.987 29.482 65.0 7.986 29.541 70.0 7.988 29.536 75.1 7.992 29.597 80.2 7.994 29.644 85.2 7.996 29.639 90.1 7.990 29.720 95.1 8.012 29.826 100.1 8.008 29.812 105.1 8.094 30.208 110.1 8.103 30.313 115.3 8.118 30.371 120.1 8.118 30.399 125.1 8.116 30.367 130.1 8.119 30.391 135.0 8.119 30.418 140.1 8.126 30.426 145.1 8.142 30.518 150.2 8.144 30.520 155.0 8.141 30.547 160.0 8.145 30.547 165.1 8.154 30.563 170.0 8.155 30.595 175.1 8.152 30.587 180.0 8.156 30.615 185.0 8.159 30.618 190.1 8.156 30.562 195.0 8.160 30.615 200.1 8.159 30.602 205.2 8.162 30.616 210.0 8.172 30.697 215.2 8.178 30.706 220.0 8.174 30.692 225.1 8.177 30.695 230.3 8.182 30.739 235.1 8.187 30.771 240.1 8.211 30.974 245.1 8.217 31.000 250.0 8.221 31.010