*2013/12/16 14:16:15.42 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/19 08:39:00.000 NUMBER OF RECORDS : 34 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.1 125.2 2 Temperature 'deg C (IPTS68)' 8.296 8.473 3 Salinity ppt 29.686 32.337 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : F 14 EVENT NUMBER : 21 LATITUDE : 48 13.50000 N ! (deg min) LONGITUDE : 122 56.50000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:13:24 97 97 DELETE 4.4 2000/01/25 13:56:25 97 34 HDREDIT2 1.6 2003/06/13 11:45:02 ? ? CLEAN 4.2 2003/06/13 11:45:30 34 34 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:15 34 34 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.1 8.456 29.694 0.3 8.454 29.694 0.4 8.454 29.713 0.5 8.454 29.700 0.7 8.466 29.690 1.0 8.467 29.697 2.0 8.473 29.699 3.1 8.459 29.698 4.1 8.450 29.692 5.0 8.464 29.686 10.1 8.413 29.813 15.0 8.407 29.912 20.1 8.379 30.225 25.0 8.351 30.358 30.1 8.336 30.419 35.1 8.304 30.584 40.1 8.316 31.245 45.1 8.345 31.342 50.1 8.353 31.384 55.0 8.370 31.438 60.1 8.375 31.539 65.1 8.374 31.561 70.1 8.366 31.637 75.2 8.359 31.664 80.1 8.351 31.690 85.3 8.350 31.727 90.1 8.348 31.819 95.2 8.337 31.881 100.1 8.332 31.971 105.2 8.328 32.004 110.2 8.322 32.057 115.2 8.316 32.100 120.0 8.313 32.162 125.2 8.296 32.337