*2013/08/06 10:36:18.39 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : GMT 1962/10/03 13:00:00.000 NUMBER OF RECORDS : 17 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 Q_DATE_TIME : 1 ! custom item Q_RECORD : 1 ! custom item QC_VERSION : OCN0 ! custom item $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------------- -------- -------------- -------------- 1 Depth metres 0 298 2 Temperature:Reversing 'deg C' 5.41 10.8 3 Salinity:Bottle ppt 32.026 33.836 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 F ' ' 0 2 -99 ' ' 7 F ' ' 2 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file was created by MEDS MEDS File name : 180262790_0134 Data quality is expressed with the following flags 0 = not checked 1 = appears to be good 2 = inconsistent with climatology 3 = appears to be doubtful 4 = appears to be wrong 5 = value was changed, see the history record Q_DATE_TIME is the quality of the date/time Q_RECORD is the worst quality flag for the entire station expressed as 1,2,3,5,4,0 from best to worst QC_VERSION is the version of quality control software used Parameter DUP_FLAG DIGIT_CODE STANDARD -------------------- -------- -------- -------- Temperature 0 0 1 Salinity: Pre-1978 0 0 S DUP_FLAG indicates if another profile exists in MEDS that is of higher quality (0=N= no duplicate) DIGIT_CODE indicates the type of digitization used STANDARD indicates the precision of the observation $END *ADMINISTRATION MISSION : 1962-90 AGENCY : PACIFIC OCEANOGRAPHIC GROUP COUNTRY : Canada PROJECT : Monitor Project SCIENTIST : Crean P.B. PLATFORM : Oshawa *LOCATION GEOGRAPHIC AREA : Dixon Entrance STATION : 134 EVENT NUMBER : 134 LATITUDE : 54 25.00000 N ! (deg min) LONGITUDE : 132 1.00000 W ! (deg min) Q_POS : 1 ! custom item DEPTH : 320.000 ! custom item WDIR : 270.000 ! custom item WSPD : 4.000 ! custom item ATMS : 997.000 ! custom item DRYT : 8.300 ! custom item WETT : 7.700 ! custom item CLCM : 8 ! custom item WWCD : 60 ! custom item QCP$ : 0001FFDE ! custom item QCF$ : 00000000 ! custom item $REMARKS Q_POS is the quality of the position Other custom items are defined by GF3 or MEDS codes $END *INSTRUMENT TYPE : Bottle:Wire *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- HDREDIT2 2.5.1 2010/03/03 21:15:38 ? ? HDREDIT2 2.5.1 2010/03/31 21:41:37 ? ? REMOVECH 8.1.1 2013/08/05 16:12:31 17 17 CHGUNITS 3.0 2013/08/05 16:13:15 17 17 HDREDIT2 2.6 2013/08/05 16:14:25 ? ? CLEAN 5.1 2013/08/06 10:36:18 17 17 $END $REMARKS -HEADER EDITS: 2010/03/03 21:15:38 Applied edit header: C:\data\edit_header.txt Channel 1: Depth [meters] Units: Metres ==> meters Channel 2: Temperature:Reversing [Degrees C] Name: Temperature ==> Temperature:Reversing Units: Degrees_C ==> Degrees C Pad: 9999.99 ==> -99 Channel 4: Salinity: Pre-1978 [PPT] Pad: 9999.99 ==> -99 -HEADER EDITS: 2010/03/31 21:41:37 Channel 4: Salinity:Bottle [PPT] Name: Salinity: Pre-1978 ==> Salinity:Bottle Channel 5: Quality_Flag:Salinity [IGOSS_flags] Name: Quality_Flag:Sali ==> Quality_Flag:Salinity -REMOVECH 2013/08/05 16:12:31 2 channels removed. -CHANGE units: - No units changed -HEADER EDITS: 2013/08/05 16:14:25 Applied edit header: P:\Cruise_Data_Processing\Data Recovery Project\1962\6290\recovery-hdr.txt Channel 3: Salinity:Bottle [ppt] Units: PPT ==> ppt Format: F7.2 ==> F8.3 Channel 1: Depth [metres] Units: meters ==> metres Pad: 9999.99 ==> -99 Channel 2: Temperature:Reversing [deg C] Units: Degrees C ==> deg C -CLEAN functions: 2013/08/06 10:36:15 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. Delete Empty Channels: 0 deleted. $END *COMMENTS Contents: Sample collection methods: Sea Water Temp - reversing thermometers mounted on Reversing Bottle samplers using Nansen bottles. Salinity - Collected in Reversing Bottle samplers Dissolved Oxygen - Collected in Reversing Bottle samplers Sample analysis methods: Sea Water Temp - Shipboard reading of reversing thermometers of German (Richter & Wiese) or Japanese (Yoshino Keiki). Salinity - Samples drawn into 8 oz. glass medicine bottles and sealed with a plastic-lined screw cap. - Laboratory analysis with conductivity salinometer. - Salinities are the means of duplicate determinations. Dissolved Oxygen - Aliquots were drawn first into 300 ml B.O.D. bottles. - Shipboard analysis - Modified Winkler method - see reference manual by Strickland 1958a, 1958b References: 1. Fisheries Research Board of Canada Manuscript Report Series, (Oceanographic and Limnological), No. 142 Oceanographic Data Record, North Pacific Survey May 23 to July 5, 1962. IOS Library: FRB-MR-OL-142. Quality flags had been added to the files but are not found in the original data files or published report, and do not look appropriate. They were removed. ----------------------------------------------------------------------------------------- !-1-- --2--- ---3--- !Dept Temper Salinit !h ature: y: ! Revers Bottle ! ing !---- ------ ------- *END OF HEADER 0. 10.80 32.048 5. 10.64 32.026 10. 10.02 32.089 20. 9.69 32.194 30. 9.18 32.209 40. 8.70 32.350 60. 7.76 32.615 79. 7.36 32.823 99. 6.99 32.977 119. 6.44 33.257 139. 6.08 33.435 159. 5.86 33.570 179. 5.71 33.653 199. 5.58 33.720 223. 5.46 33.809 248. 5.44 33.827 298. 5.41 33.836