*2004/05/25 13:38:26.35 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 1956/09/25 18:12:00.000 NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 5 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ----------------------- --------- -------------- -------------- 1 Depth metres 0 156 2 Temperature:Reversing 'deg C' 3.86 12.7 3 Salinity:Bottle ppt 32.74 33.77 4 Oxygen:Dissolved mL/L 3.57 7.04 5 Oxygen:Dissolved umol/kg 155.2178 291.9708 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 6 F ' ' 0 2 -99 ' ' 7 F ' ' 2 3 -99 ' ' 7 F ' ' 2 4 -99 ' ' 7 F ' ' 2 5 -99 ' ' 6 F ' ' 1 $END *ADMINISTRATION MISSION : 1956-01 AGENCY : POG, Nanaimo, B.C. COUNTRY : CANADA PROJECT : Station P SCIENTIST : Bennett E.B. PLATFORM : St. Catharines *LOCATION GEOGRAPHIC AREA : NE PACIFIC STATION : P EVENT NUMBER : 6 LATITUDE : 50 0.00000 N ! (deg min) LONGITUDE : 145 0.00000 W ! (deg min) *INSTRUMENT TYPE : Bottle MODEL : Fjarlie reversing *COMMENTS This file was obtained from the publication "Fisheries Research Board of Canada, Pacific Oceanographic Group. Data Record 1956. Ocean weather station "PAPA" (50:00'N, 145:00'W), Joint Committee on Oceanography, page 115". Additional comments from John Pages files. Contents: Cast data from Weathership program using ships C.G.S. "St. Catharines" and C.G.S. "Stonetown" from Vancouver Island, BC, Canada to Ocean Weather Station P [50N x 145W] Sample collection methods: Sea Water Temp reversing thermometers mounted on Reversing Bottle samplers Salinity collected in Reversing Bottle samplers Dissoved Oxygen Collected in Reversing Bottle samplers Sample analyses methods: Sea Water Temp: Shipboard reading of reversing thermometers Salinity: Shore lab analyses. A modified Mohr titration method was used. Dissolved Oxygen: Shipboard analyses. A modified Winkler method was employed, using 125 ml. samples. Inorganic Phosphate: Shipboard analyses. One hundred ml. samples were drawn in 125 ml. bottles and brought to room temperature. The method of Robinson and Thompson (1948) was employed. Inorganic Nitrate: Shipboard analyses. Analyses were done on 1 ml. sample using reduced strychnine method as modified by by Marvin (1955). Inorganic Nitrite: Shipboard analyses. Analyses were done on a 50 ml. sample according to the method of Bendschneider and Robinson (1952). pH: Shipboard analyses. Measurements were made with a Beckman model G meter. Alkalinity: Shipboard analyses. The method of Anderson (1946) was used. The pH of a 100 ml. seawater sample to which 25 ml. of 0.01 N hydrochloric acid had been added was determined and used to calculate the milli-equivalents of hydrogen ion neutralized by one liter of sea water at a temperature of 20 degrees C. References: 1. Hollister, H.J. 1956. The program of bathythermograph observations at the Canadian ocean weather station "PAPA" (50:00'N, 145:00'W). MS Report, Fisheries Research Board of Canada, Pacific Oceanographic Group, Nanaimo, B.C. 2. Fisheries Research Board of Canada, Pacific Oceanographic Group. 1957 Data Record 1956. Ocean weather station "PAPA" (50:00'N, 145:00'W). MS report, Joint Committee on Oceanography 3. Fisheries Research Board of Canada Manuscript Report Series, (Oceanographic and Limnological), No. 187 Oceanographic Atlas of Ocean Weather Station "Papa" 1956-1963 IOS Library: FRB-MR-OL-187 4. Annual FRB Report of the Pacific Oceanographic Group, Biological Station, Nanaimo, B.C. 5. Above references at Institute of Ocean Sciences Library, Sidney, B.C. *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- CALIB 10.2 2002/01/24 16:13:36 7 7 CHGUNITS 1.2 2002/01/24 17:24:14 7 7 HDREDIT2 1.3 2002/01/25 14:08:31 ? ? HDREDIT2 1.3 2002/01/25 16:41:39 ? ? HDREDIT2 1.3 2002/02/06 14:11:51 ? ? HDREDIT2 1.3 2002/02/18 09:02:34 ? ? REMOVECH 6.0 2004/05/18 13:42:00 7 7 CHGUNITS 1.4 2004/05/18 13:43:26 7 7 HDREDIT2 2.1 2004/05/25 13:38:26 ? ? $END $REMARKS -The following CALIB parameters were used: Calibration type = Raw Mode: ONLY - calibration specs from Cal File only. Calibration file = L:\CTD\WORK\CALIB\Oxygen.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 4 Oxygen mL/L 10 0.0000000E+00 0.1120000E+02 CHANGE units: - Units changed from ml/l to umol/l -The following CHANNEL(S) were removed from file. Oxygen:Dissolved:Mass CHANGE units: - Units changed from mL/L to umol/kg $END *CALIBRATION $TABLE: RAW CHANNELS ! Name Units Fmla Pad Coefficients ! -------- ------ ---- ------ ------------ Oxygen mL/L 10 -99 (0 11.2) $END !--1-- --2--- --3--- --4--- --5-- !Depth Temper Salini Oxygen Oxyge ! ature: ty: : n: ! Revers Bottle Dissol Disso ! ing ved lved !----- ------ ------ ------ ----- *END OF HEADER 0. 12.70 32.74 6.05 263.6 69. 4.41 32.77 6.71 292.0 87. -99.00 32.82 7.04 -99.0 104. 3.86 32.86 6.50 282.8 121. 4.05 33.32 5.33 231.8 139. 4.18 33.56 4.40 191.3 156. 4.24 33.77 3.57 155.2