*2013/09/27 11:56:45.37 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2010/08/21 22:28:00.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 2 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 12842F6D NUMBER OF CHANNELS : 22 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 149 150 2 Bottle_Number n/a 1 2 3 Bottle:Firing_Sequence n/a 1 2 4 Pressure:CTD dbar 6.3 30.3 5 Temperature:CTD deg_C_(ITS90) 11.9095 15.0914 6 Salinity:Practical:CTD PSS-78 31.7731 32.1327 7 Sigma-t:CTD kg/m^3 23.4923 24.4059 8 Transmissivity:CTD %/m 43 53.7 9 Oxygen:Dissolved:CTD:Volume ml/l 5.93 6 10 Oxygen:Dissolved:CTD:Mass µmol/kg 258.4 261.5 11 Fluorescence:CTD:Seapoint mg/m^3 0.7 1.188 12 Salinity:Bottle PSS-78 31.7767 31.7767 13 Flag:Salinity:Bottle n/a 14 Nitrate_plus_Nitrite:Bottle µmol/l 0.5 3.6 15 Flag:Nitrate_plus_Nitrite:Bottle n/a 16 Phosphate:Bottle µmol/l 0.42 0.73 17 Flag:Phosphate:Bottle n/a 18 Silicate:Bottle µmol/l 4.6 5.3 19 Flag:Silicate:Bottle n/a 20 Chlorophyll:Extracted:Bottle mg/m^3 0.6 0.81 21 Flag:Chlorophyll:Extracted:Bottle n/a 22 Phaeo-Pigment:Extracted:Bottle mg/m^3 0.2 0.35 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I ' ' 2 -99 ' ' 3 I I 0 3 -99 ' ' 3 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 9 F R4 4 8 -99 ' ' 6 F ' ' 1 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 9 F ' ' 4 12 -99 ' ' 9 F R4 4 13 0 ' ' 3 NQ C ' ' 14 -99 ' ' 6 F R4 1 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' 7 F R4 2 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' 6 F R4 1 19 0 ' ' 3 NQ C ' ' 20 -99 ' ' 7 F R4 2 21 0 ' ' 3 NQ C ' ' 22 -99 ' ' 7 F R4 2 $END *ADMINISTRATION MISSION : 2010-14 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P10 EVENT NUMBER : 26 LATITUDE : 48 53.68000 N ! (deg min) LONGITUDE : 129 39.98000 W ! (deg min) WATER DEPTH : 2642 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 LOCATION : Mid-ship ! custom item *COMMENTS Samples Number 149 and 150: Phophate:Bottle - rerun. Analysis methods: ----------------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -20C prior to analysis. Samples were extracted in 90% acetone for 24 hours and analyzed at sea on a Turner 10AU fluorometer which is calibrated annually with commercially pure chlorophyll a (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen 1965). Chlorophyll and Phaeo-Pigments precision was determined by analyzing replicate samples drawn from one Niskin. For details see file 2010-14_CHL.pdf. Phaeopigment data are provided for information only and no quality flags are assigned to them. Oxygen samples were analyzed at sea using an automated Winkler titration system with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). The titration system consists of a Brinkmann 665 Dosimat, a UV light source and a UV detector with a 365nm filter custom built by Scripps Institution of Oceanography. For details see file 2010-14_OXY.pdf Salinity samples were collected in glass bottles and analyzed at IOS on a Guildline model 8400B Autosal standardized with IAPSO standard seawater. For information on duplicates see file 2010-14_SAL.pdf. Nutrient samples were collected in plastic tubes. Most samples were analyzed frozen at IOS using an Astoria autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). Deep silicate samples (400 dbar and below) were analyzed cool at IOS. For details on nutrient duplicates and precision see file 2010-14_NUT.pdf. NOTE: July 2013: A correction has been applied to Nitrate_plus_Nitrite:Bottle and Phosphate:Bottle data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the report: Corrections_to_Nitrate_and_Phosphate_Data_2009-2012.pdf. The minimum detectable level for DMS is 0.10 nM, so “0” values should be interpreted as <0.10. For details on the collection and analysis of the DMS data see file 2010-14_DMS_Report.pdf. For details on duplicates see 2010-14_DMS.pdf References: 1. Holm-Hansen, O., C. J. Lorenzen, R.W. Holmes and J.D.H. Strickland. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C. H., and R. T. Williams. 1991. A comparison of methods for the determination of dissolved oxygen in seawater. Report No. WHPO 91-2. WOCE Hydrographic Programme Office. Woods Hole Oceanographic Institution, Woods Hole, Mass. 4. Barwell-Clarke, J. and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. --------------------------------------------------------------------- Fluorescence, Transmissivity and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. The quality of the Oxygen:Dissolved:CTD data is lower than usual for both sensors because recalibration was based on observations from very few casts, and the fits of bottles against CTD produced significantly different fits for some casts from others. Similar problems were found in sensor #1176 (CTD #0506) on some other 2010 cruises and appear to be associated with CTD communication problems. For details see the processing report 2010-14-proc.pdf. NOTE: July 2013: A correction has been applied to Nitrate_plus_Nitrite:Bottle and Phosphate:Bottle data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the report: Corrections_to_Nitrate_and_Phosphate_Data_2009-2012.pdf. $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END !-1-- 2- 3- --4--- ---5---- ---6---- ---7---- --8-- --9--- --10- ---11--- ---12--- 13 --14- 15 --16-- 17 --18- 19 --20-- 21 --22-- !Samp Bo Bo Pressu Temperat Salinity Sigma-t: Trans Oxygen Oxyge Fluoresc Salinity Fl Nitra Fl Phosph Fl Silic Fl Chloro Fl Phaeo- !le_ tt tt re:CTD ure:CTD : CTD missi :Disso n:Dis ence: :Bottle ag te_pl ag ate: ag ate: ag phyll: ag Pigmen !Numb ~u ~u Practica vity: lved: solve CTD: ~o ~Nitr ~o Bottle ~o Bottl ~o Extrac ~o t:Extr !er mb en l:CTD CTD CTD: d:CTD Seapoint tt ite:B tt tt e tt ted: tt acted: ! er ce Volume :Mass le ottle le le le Bottle le Bottle !---- -- -- ------ -------- -------- -------- ----- ------ ----- -------- -------- -- ----- -- ------ -- ----- -- ------ -- ------ *END OF HEADER 150 2 2 6.3 15.0914 31.7731 23.4923 43.0 6.00 261.5 0.7000 31.7767 0.5 0.42 4.6 0.60 6 0.20 149 1 1 30.3 11.9095 32.1327 24.4059 53.7 5.93 258.4 1.1880 -99.0000 3.6 0.73 5.3 0.81 6 0.35