*2013/10/08 13:34:34.10 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2009/08/20 18:03:17.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : CE484D23 NUMBER OF CHANNELS : 21 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 21 28 2 Bottle_Number n/a 1 8 3 Pressure:CTD dbar 5.5 106.4 4 Temperature:CTD deg_C_(ITS90) 7.0302 12.3191 5 Salinity:Practical:CTD PSS-78 32.2957 33.8327 6 Sigma-t:CTD kg/m^3 24.4558 26.521 7 Transmissivity:CTD %/m 30.9 45 8 Oxygen:Dissolved:CTD:Volume ml/l 1.61 5.86 9 Oxygen:Dissolved:CTD:Mass µmol/kg 70 255.7 10 Fluorescence:CTD:Seapoint mg/m^3 0.118 2.784 11 PAR:CTD µE/m^2/sec 0 78.8 12 Salinity:Bottle PSS-78 32.2991 33.8275 13 Flag:Salinity:Bottle n/a 14 Oxygen:Dissolved:Bottle:Volume ml/l 1.536 5.86 15 Flag:Oxygen:Dissolved:Bottle n/a 16 Nitrate_plus_Nitrite:Bottle µmol/l 16.4 34.2 17 Flag:Nitrate_plus_Nitrite:Bottle n/a 18 Phosphate:Bottle µmol/l 1.47 2.69 19 Flag:Phosphate:Bottle n/a 20 Silicate:Bottle µmol/l 35.8 56.6 21 Flag:Silicate:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 9 F R4 4 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 7 F ' ' 2 9 -99 ' ' 6 F ' ' 1 10 -99 ' ' 8 F ' ' 3 11 -99 ' ' 7 F ' ' 1 12 -99 ' ' 9 F R4 4 13 0 ' ' 3 NQ C ' ' 14 -99 ' ' 8 F R4 3 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' 6 F R4 1 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' 7 F R4 2 19 0 ' ' 3 NQ C ' ' 20 -99 ' ' 6 F R4 1 21 0 ' ' 3 NQ C ' ' $END *ADMINISTRATION MISSION : 2009-10 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P2 EVENT NUMBER : 6 LATITUDE : 48 35.92000 N ! (deg min) LONGITUDE : 125 59.46000 W ! (deg min) WATER DEPTH : 115 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 LOCATION : Mid-ship ! custom item *COMMENTS Sample Number 22: All samples - Bottle Number 2 did not close. Sample Number 23: Salinity:Bottle - lid loose on both of duplicate samples; Oxygen:Dissolved:Bottle - duplicate taken but lid was off so not used. Samples Number 21 to 28: Oxygen:Dissolved:Bottle - flags explained in Analysis methods below. Analysis methods: ----------------- Chlorophyll samples were analyzed at sea using a Chemistry Turner Designs 10AU fluorometer which was calibrated on May 13, 2009 using pure chlorophyll a. Chlorophyll precision was determined by analyzing replicate samples drawn from one Niskin. For details see file 2009-10_CHL.pdf. Oxygen samples were analyzed at sea using an automated titration system consisting of a Brinkman Dosimat (model 765) and a PC 950 Colorimeter. For information on precision see file 2009-10_OXY.pdf. The thiosulphate titer of 0.709 obtained during standardization was low and out of range leading to a suspected overestimate in Oxygen:Dissolved:Bottle value of ~2.5%. This is believed to be due to either a bad batch of standard or incorrect calibration parameters (temperature or volume dispensed). Comparison to the Oxygen:Dissolved:CTD data confirmed the likely Oxygen:Dissolved: Bottle data overestimate using the original 0.709 titer. The Oxygen:Dissolved:Bottle data were thus recalculated using the mean thiosulfate titer for the year (0.721). Recalculated results are consistent with a post-cruise calibration of the Oxygen:Dissolved:CTD sensor. All samples are flagged "4" since the data are considered to be of lower quality than usual. Salinity samples were collected in glass bottles and analyzed at IOS on a Guildline model 8400B Autosal standardized with IAPSO standard seawater. Samples from two casts were analyzed at sea on a Guildline Portasal; there are comments attached to those samples and all were flagged "4". See file 2009-10_SAL.pdf for information on Autosal precision. Nutrient samples were collected in plastic tubes and analyzed fresh at sea using an Astoria Pacific autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). For details on nutrient duplicates and precision see file 2009-10_NUT.pdf. NOTE: July 2013: A correction has been applied to Nitrate_plus_Nitrite:Bottle and Phosphate:Bottle data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the report: Corrections_to_Nitrate_and_Phosphate_Data_2009-2012.pdf. The minimum detectable level for DMS is 0.10 nM, so “0” values should be interpreted as <0.10. For details on the collection and analysis of the DMS data see file 2009-10_DMS_report.pdf. For duplicates see file 2009-10_DMS.pdf. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. --------------------------------------------------------------------- For details on the processing see processing report: 2010-01-proc.pdf NOTE: July 2013: A correction has been applied to Nitrate_plus_Nitrite:Bottle and Phosphate:Bottle data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the report: Corrections_to_Nitrate_and_Phosphate_Data_2009-2012.pdf. $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END !-1-- 2- --3--- ---4---- ---5---- ---6---- --7-- --8--- --9-- ---10-- --11-- ---12--- 13 ---14-- 15 --16- 17 --18-- 19 --20- 21 !Samp Bo Pressu Temperat Salinity Sigma-t: Trans Oxygen Oxyge Fluores PAR: Salinity Fl Oxygen: Fl Nitra Fl Phosph Fl Silic Fl !le_ tt re:CTD ure:CTD : CTD missi :Disso n:Dis cence: CTD :Bottle ag Dissolv ag te_pl ag ate: ag ate: ag !Numb ~u Practica vity: lved: solve CTD: ~o ed: ~o ~Nitr ~o Bottle ~o Bottl ~o !er mb l:CTD CTD CTD: d:CTD Seapoin tt Bottle: tt ite:B tt tt e tt ! er Volume :Mass t le Volume le ottle le le le !---- -- ------ -------- -------- -------- ----- ------ ----- ------- ------ -------- -- ------- -- ----- -- ------ -- ----- -- *END OF HEADER 28 8 5.5 12.3191 32.2957 24.4558 30.9 5.86 255.7 2.591 78.8 32.2991 5.860 4 16.4 1.47 36.1 27 7 11.2 11.6348 32.3207 24.6022 31.5 5.69 247.9 2.784 19.5 32.3203 5.739 4 16.8 6 1.52 6 35.8 6 26 6 26.3 9.6984 32.5726 25.1326 38.6 4.39 191.4 1.687 1.0 32.5464 4.542 4 21.0 1.80 36.2 25 5 51.4 8.0504 33.0503 25.7614 45.0 2.66 115.9 0.196 0.0 33.0472 2.662 4 30.1 6 2.46 6 47.5 6 24 4 76.2 7.8217 33.1883 25.9030 44.8 2.18 94.7 0.142 0.0 33.1789 2.168 4 32.3 2.64 53.4 23 3 76.0 7.8268 33.1849 25.8995 44.7 2.17 94.5 0.142 0.0 33.1795 6 2.167 4 32.4 2.64 53.5 22 2 102.3 7.0681 33.8032 26.4926 37.2 1.71 74.4 0.126 0.0 -99.0000 9 -99.000 9 -99.0 9 -99.00 9 -99.0 9 21 1 106.4 7.0302 33.8327 26.5210 36.1 1.61 70.0 0.118 0.0 33.8275 1.536 4 34.2 2.69 56.6