*2013/08/12 15:53:05.12 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2011/08/23 08:59:28.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 2 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 7FF7E87B NUMBER OF CHANNELS : 25 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 342 343 2 Bottle_Number n/a 1 2 3 Bottle:Firing_Sequence n/a 1 2 4 Pressure:CTD dbar 4.6 53.9 5 Temperature:CTD deg_C_(ITS90) 7.4038 14.0384 6 Salinity:Practical:CTD PSS-78 32.415 32.6358 7 Sigma-t:CTD kg/m^3 24.2086 25.5277 8 Transmissivity:CTD %/m 55.7 59.7 9 Oxygen:Dissolved:CTD:Volume ml/l 6.11 7.1 10 Oxygen:Dissolved:CTD:Mass µmol/kg 266.2 309 11 Fluorescence:CTD:Wetlabs mg/m^3 1.653 1.996 12 Salinity:Bottle PSS-78 32.4158 32.4158 13 Flag:Salinity:Bottle n/a 14 Oxygen:Dissolved:Bottle:Volume ml/l 6.111 6.111 15 Oxygen:Dissolved:Bottle:Mass µmol/kg 266.4 266.4 16 Flag:Oxygen:Dissolved:Bottle n/a 17 Nitrate_plus_Nitrite:Bottle µmol/l 5.1 8.1 18 Flag:Nitrate_plus_Nitrite:Bottle n/a 19 Phosphate:Bottle µmol/l 0.76 0.98 20 Flag:Phosphate:Bottle n/a 21 Silicate:Bottle µmol/l 10 12.9 22 Flag:Silicate:Bottle n/a 23 Chlorophyll:Extracted:Bottle mg/m^3 0.23 0.28 24 Flag:Chlorophyll:Extracted:Bottle n/a 25 Phaeo-Pigment:Extracted:Bottle mg/m^3 0.14 0.23 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 3 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 9 F R4 4 8 -99 ' ' 6 F ' ' 1 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 8 F ' ' 3 12 -99 ' ' 9 F R4 4 13 0 ' ' 3 NQ C ' ' 14 -99 ' ' 8 F R4 3 15 -99 ' ' 6 F ' ' 1 16 0 ' ' 3 NQ C ' ' 17 -99 ' ' 6 F R4 1 18 0 ' ' 3 NQ C ' ' 19 -99 ' ' 7 F R4 2 20 0 ' ' 3 NQ C ' ' 21 -99 ' ' 6 F R4 1 22 0 ' ' 3 NQ C ' ' 23 -99 ' ' 7 F R4 2 24 0 ' ' 3 NQ C ' ' 25 -99 ' ' 7 F R4 2 $END *ADMINISTRATION MISSION : 2011-27 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P17 EVENT NUMBER : 49 LATITUDE : 49 20.98000 N ! (deg min) LONGITUDE : 135 39.96000 W ! (deg min) WATER DEPTH : 3707 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 LOCATION : Mid-ship ! custom item *COMMENTS Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -20C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours and analyzed on a Turner 10AU fluorometer which is calibrated annually with commercially pure chlorophyll a (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed on board ship in a controlled temperature lab. When duplicate samples were collected the average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). For details see file 2011-27_CHL.pdf. Phaeopigment data are provided for information only and no quality flags are assigned to them. Oxygen samples were analyzed on an automated Winkler titration system (Brinkmann Dosimat model 765 and a PC950 Colorimeter controlled by AutoOxy software V3.4) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). All samples were analyzed at sea. For details including a duplicate analysis, see file 2011-27_OXY.pdf. Salinity samples were collected in 200 ml type ll glass bottles with plastic inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer (S/N 68572) standardized with IAPSO standard seawater 5 months after collection. Full details are in file 2011-27_SAL.pdf. Nutrient samples were collected in plastic tubes. Most samples were analyzed fresh at sea. A few loop samples were analyzed frozen at IOS. An Astoria analyzer was used following methods described in Barwell-Clarke and Whitney (1996). See file 2011-27_NUT.pdf for duplicates and precision information. NOTE: July 2013: A correction has been applied to Nitrate_plus_Nitrite:Bottle and Phosphate:Bottle data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the report: Corrections_to_Nitrate_and_Phosphate_Data_2009-2012.pdf. The minimum detectable level for DMS is 0.10 nM, so “0” values should be interpreted as <0.10. For details on the collection and analysis of the DMS data see file 2011-27_DMS_Report.pdf. See file 2011-27_DMS.pdf for duplicates and precision study. References: 1. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. --------------------------------------------------------------------------- Fluorescence, Transmissivity and PAR data are nominal and unedited. For details on how the transmissivity calibration parameters were calculated see the document Transmissivity_Calculation.pdf. The Oxygen:Dissolved:CTD calibration was done using the method described in the Sea-Bird Application Note #64-2 (Sea-Bird_64-2_Feb2010.pdf). For details on the processing see processing report: 2011-27-proc.pdf NOTE: July 2013: A correction has been applied to Nitrate_plus_Nitrite:Bottle and Phosphate:Bottle data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the report: Corrections_to_Nitrate_and_Phosphate_Data_2009-2012.pdf. $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END !-1-- 2- 3- --4--- ---5---- ---6---- ---7---- --8-- --9--- --10- ---11-- ---12--- 13 ---14-- --15- 16 --17- 18 --19-- 20 --21- 22 --23-- 24 --25-- !Samp Bo Bo Pressu Temperat Salinity Sigma-t: Trans Oxygen Oxyge Fluores Salinity Fl Oxygen: Oxyge Fl Nitra Fl Phosph Fl Silic Fl Chloro Fl Phaeo- !le_ tt tt re:CTD ure:CTD : CTD missi :Disso n:Dis cence: :Bottle ag Dissolv n:Dis ag te_pl ag ate: ag ate: ag phyll: ag Pigmen !Numb ~u ~u Practica vity: lved: solve CTD: ~o ed: ~ed:B ~o ~Nitr ~o Bottle ~o Bottl ~o Extrac ~o t:Extr !er mb en l:CTD CTD CTD: d:CTD Wetlabs tt Bottle: ottle tt ite:B tt tt e tt ted: tt acted: ! er ce Volume :Mass le Volume :Mass le ottle le le le Bottle le Bottle !---- -- -- ------ -------- -------- -------- ----- ------ ----- ------- -------- -- ------- ----- -- ----- -- ------ -- ----- -- ------ -- ------ *END OF HEADER 343 2 2 4.6 14.0384 32.4150 24.2086 55.7 6.11 266.2 1.653 32.4158 6.111 266.4 5.1 0.76 10.0 0.23 0.14 342 1 1 53.9 7.4038 32.6358 25.5277 59.7 7.10 309.0 1.996 -99.0000 -99.000 -99.0 8.1 0.98 12.9 0.28 0.23